Rafiki twinflex installation manual

The control panels are available in 2, 4 and 8 zones. Welcome to the sd fire alarms fike twinflex pro panel description part 1 video. Able to run detectors and sounders on the same pair of wires, the twinflex pro is an 8 zone two wire panel. Advantages of the twinflex system are a significant reduction in cabling costs and a neater installation.

Whilst every care has been taken to ensure that the contents of this document are correct at time of publication, rafiki shall be under no liability whatsoever in. This product has now been replaced by the 505 0004 unit which can be used as a like for like replacement. I have phoned rafiki helpline on this topic and they have no experience of this being a. This time, we have the pleasure to collaborate with one of our. Twinflex and multipoint installation and operating instructions rafiki protection limited 55 springvale industrial estate cwmbran south wales np44 5bd. Twinflex pro control panel user guide 2 fikes policy is one of continual improvement and the right to change a specification at any time without notice is reserved. Rafiki twinflex two wire fire alarm control panel 2 zone 502 0002. It gets embarrassing to have to go to the same house 3 times a month to sort out the same problem. Mounted in a standard double gang box, including two sets of 2a rated spco relay contacts, one monitored input and inbuilt end of line. Rafiki twinflex two wire fire alarm panel 2 zone 502 0002 rafiki twinflex two wire fire alarm panel 2 zone 502 0002. Rafiki protection is a well known uk manufacturer of rafiki fire alarm equipment renowned for quality and value. The rafiki fike twinflex is a two wire fire alarm system. Using internal product development, scientific research, and testing and validation capabilities, fike develops applicationspecific solutions consistent with the worlds codes, standards and regulations.

Emc this equipment when installed is subject to the emc directive 2004108ec. Fike rafiki twinflex 4 zone fire alarm kit white quick specifications. Twinflex pro osp software operating instructions 4 introduction twinflex pro osp is the name given to the high level software package written to enable the individual configuration of the twinflex pro fire alarm systems. A fire alarm is annunciated when a detector detects smoke or heat, a manual call point is. Introducing rafiki twinflex, conventional fire alarm. I have a fike twinflex system with a 4020006 manual callpoint as the first item in the chain, followed by 8 sensors then another manual callpoint 4020006 at the end of the chain.

Without the need to run additional sounder circuits. The subsequent actions depend on the actual configuration but generally. Introducing rafiki twinflex, conventional fire alarm systems. This product has now been replaced by the 505 0002 panel which can be used as a replacement. Twinflex v3 control panel user guide 7 the standard specifies a number of maintenance tasks which include a visual inspection of the installation to ensure that there are no alterations or obstructions which could affect the operation of the system, and functional checks to confirm the operation of the system. Including main control panels, optical smoke and heat detectors, combined detectors with sounder, manual call points, manual call points with built in sounder, beacons, sounder and interfaces. I look after quite a few systems in student properties and i get the same problems as you. Twinflex pro control panel engineering and commissioning manual 5 introduction this manual is intended as a guide to the engineering and commissioning principles of the twinflex pro 2wire fire detection and alarm system and covers the system hardware information only. Twinflex v3 user guide gardiner fire and security alarms ltd. Rafiki twinflex fire twinflex two wire fire alarm system. To maintainemc compliance this system must be installed as defined within this manual. View and download fike twinflexpro user manual online.

For more information on these products call us now on 01200 428 410 or use the livechat facility below. The panel is showing a power fault which is obviously the batteries as the voltage is only 19volts, but the panel has also shows a fault. Callpoint identification panel can differentiate between callpoint or detector alarms. Twinflex user guide 2 rafiki protection limited rafiki policy is one of continual improvement and the right to change a specification at any time without notice is reserved. Installation and maintenance instructions 2040003 twinflex multipoint asd detector, 2040001 twinflex multipoint asd with sounder, 2040012 twinflex multipoint asd with sounder strobe 260947 issue 7 190614 general description the twinflex multipoint asd is a plugin type smoke detector that utilises a. Rafiki twinflex two wire fire alarm system detectors. This means that the detectors, call points, sounders and beacons can all be installed on the same radial zone circuit reducing the need to install seperate detection and sounder circuits. This allows the installer to position detectors, call points, sounders, beacon and relays on the same zone circuit. For more information on the rafiki twinflex two wire fire alarm system call us now on 01200 428 410.

Repeater panel engineering and commissioning manual. It is also subject to uk statutory instrument 2006 no. Addressable fire alarms fire panels rafiki fire alarms. The callpoint at the end of the chain is set to eol end of line and its red light flashes as i would expect. Mar 10, 2014 welcome to the sd fire alarms fike twinflex pro panel description part 1 video. Fike twinflex manual call point, callpoints, fire protection. This is the name of the automatic detector used in the twinflex installation. The fike twinflex pro 8 zone fire alarm panel, for example, can detect and sound the alarm throughout 8 programmable zones in a building, giving you overarching protection. In practice it is far easier for the user to activate a manual call point, rather than a detector which requires. This application guide is intended primarily for system. Builtin end of line device all devices including detectors, callpoints and standalone sounders have a selectable builtin end of line monitoring function. We are the leading manufacturer of conventional 2wire fire alarm systems twinflex and analogue addressable fire alarm systems sita, duonet and quadnet. Installation and maintenance instructions 2040003 twinflex multipoint asd detector, 2040001 twinflex multipoint asd with sounder, 2040012 twinflex multipoint asd with sounder strobe 260947 issue 7 190614 general description the twinflex multipoint asd is. The rafiki twinflex is a two wire fire alarm system.

Rafiki twinflex two wire fire alarm control panel 4 zone 502 0004 please note. In addition to finding the traditional twinflex point of call alarms, you can also shop for more technically advanced systems that are ideal for use in large buildings. Rafiki twinflex two wire fire alarm panel 2 zone 502 0002. Access level 2 user operating instructions 8 zone panel. Twinflex, mulitpoint, fike and fike corporation are registered trademarks of fike corporation. Twinflex pro repeater panel engineering and commissioning manual 6. Whilst every care has been taken to ensure that the contents of this document are correct at time of publication, fike shall be under no liability whatsoever in respect of. This time, we have the pleasure to collaborate with one of our main manufacturers. Device installation all wiring must be installed in compliance with the recommendations laid out by bs5839 pt1. Rafiki twinflex two wire fire alarm panel 4 zone 502 0002. Twiflex offers the largest range of pneumatically, hydraulically, and mechanicallyapplied industrial disc brake calipers in the world, along with a full line of thrusters, disc brake systems. Twinflex fire detection systems screwfix community forum. Fike rafiki twinflex two wire fire alarm systems the safety centre are pleased to introduce the range of fike formerly rafiki two wire fire alarm system equipment.

Rafiki policy is one of continual improvement and the right to change a. Using the multipoint asd detector as part of the twinflexpro two wire fire alarm system means that when a detector is wired to the system, a sounder and strobe can also be connected without extra installation time or cost. Twinflexpro control panel engineering and commissioning manual 5 introduction this manual is intended as a guide to the engineering and commissioning principles of the twinflexpro 2wire fire detection and alarm system and covers the system hardware information only. The twinflex multipoint head is a 2wire device used with the twinflex and twinflex pro systems, whereas the addressable asd detector is used on the sita200plus, duonet and quadnet systems. Due to the complexity and inherent importance of a system covering a life protection risk, training on. Lead acid battery store official fire alarm equipment stockist have rafiki twinflex two wire fire alarm panel 4 zone 502 0004 available, so order online today. The sounder must be installed in compliance with the control panel installation manual. Installation savings as high as 40% save on cable, installation time and sounders.

Relay interfacing module with monitored input to provide shutodwn and monitoring facilties from the twinflex zone. The panel has the ability to differentiate between call point or detector alarms. Twinflex and multipoint installation and operating instructions introduction about the manual these installation and operating instructions contain information to enable an engineer to install, commission and operate the rafiki twinflex range of control panels and field devices. Twinflex and multipoint user guide 2 rafiki protection limited. The rafiki spel fpa1011 resettable manual call point is available with a. Twinflex, mulitpoint, fike and fike corporation are registered trademarks of. Safety centre have rafiki twinflex 2 zone fire alarm system contractor kit in stock, so order online now. Hi, needing some advice with a 2 zone twin flex fire alarm panel.

Download now this is achieved by adjusting switches on the detector depending on whether the detector should be a smoke or. The rafiki twinflex system uses the multipoint type detectors. Fike manufactures industrial safety products that protect people and organizations from combustible dust explosions, pressurerelated explosions and industrial fire hazards. This windows based program allows the system to be set up for each application. Twinflex pro control panel engineering and commissioning manual. Builtin end of line device all devices including detectors, callpoints and standalone sounders have a. The fike rafiki twinflex systems all fully comply to the relevant british standards and en standards. Rafiki s comprehensive fire protection range includes intelligent smoke detectors, sounders, manual call points and control panels. Whilst every care has been taken to ensure that the contents of this. Twiflex limited, founded in 1946, specializes in the design, manufacture and supply of advanced braking technologies for industrial applications. For more information on rafiki twinflex systems call us now on 01200 428 410. I have phoned rafiki helpline on this topic and they have no experience of this being a problem. Rafikis comprehensive fire protection range includes intelligent smoke detectors, sounders, manual call points and control panels.

Rv fire systems have always given their customers the best advice and service around when it comes to fire safety. Installation and maintenance instructions 2050001, 2050003 and 2050012. Fike corporation products and services are approved and listed by many agencies and authorities having jurisdiction. Rafiki twinflex 2 zone fire alarm system contractor kit. The multipoint and asd detectors have set new standards in detector technology.